Electrosurgical model: Surtron 80/120/160

SURTRON 80 / 120 / 160 is a high frequency electrosurgical equipment which is suitable to light and medium surgery.

SURTRON 80 / 120 / 160 through its performance, allows pure CUT, cut-coagulation
BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis
SOFT COAG and, with a special adapter, BIPOLAR coagulation.
The digital reading of delivered power and the monitoring of operative function by microcontroller.

SURTRON 80 / 120 / 160 The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the monopolar output functions as well as the delivery of output power.

 

Specification 

MODEL Surtron 80 Surtron 120 Surtron 160
Reference code 10100.101 10100.201 10100.301
Maximum output power CUT 80 W-250 Ω 120 W-250 Ω 160 W-250 Ω
Maximum output power BLEND 60 W-200 Ω 90 W-200 Ω 120 W-200 Ω
Maximum output power FORCED COAG 50 W-150 Ω 80 W-150 Ω 100 W-150 Ω
Maximum output power SOFT COAG 40 W-100 Ω 60 W-100 Ω 80 W-100 Ω
Maximum output power BIPOLAR 30 W-100 Ω 40 W-100 Ω 60 W-100 Ω
Working frequency 600 KHz 600 KHz 600 KHz
Patient circuit F F F
Selectable input voltage 115-230 Vac 115-230 Vac 115-230 Vac
Mains frequency 50-60 Hz 50-60 Hz 50-60 Hz
Electrical input power 230 VA 300 VA 350 VA
Size WxHxD mm 254x104x288 254x104x288 254x104x288
Weight 5 Kgs 5 Kgs 5 Kgs

 

ใบรับแจ้งรายการละเอียด เลขที่ 66-2-2-2-0010690

*อ่านคำเตือนในฉลากและเอกสารกำกับเครื่องมือแพทย์ก่อนใช้*

-----------------------------------------------------------------

Warning:

  • Electro‐surgery can be dangerous. Careless use of any element in the electrosurgical system may subject the patient to a serious burn. Read and understand all warnings, precautions, and directions for use before attempt to use any active electrode. Neither LED SpA, can be considered responsible for personal, material or consequential injury, loss or damage that results from improper use of the equipment and accessories.
  • When the electrosurgical unit is used in operating rooms it is necessary to just use waterproof foot-switches (REF 00304.00 Water-proofpedal with single switch - REF 00304,03 Water-proof pedal with double switches) 

 

Precautions: Avoid the skin to skin contact (for example between arm and body of the patient).

 

Contraindication:

Electro surgery is not recommended in the following subjects:

  • having pacemaker;
  • with stimulating electrodes;
  • with metal prosthesis plant;
  • with important arterial pressure unbalance;
  • with important nervous disorders;
  • with renal insufficiency;
  • in state of pregnancy.

Burns are the most consequences of the HF electro surgery for the patient, even if these are not the only one. In fact necrosis by compression, allergic reactions to the disinfectant, gas or inflammable liquids ignition. Some important causes of burns are by:

  • insufficient medical equipe training about all modalities to avoid or reduce the risks of burns by using HF electrosurgical units;
  • use of disinfectants with high alcol content;
  • incorrect position of the patient during the electrosurgical operation;
  • contact between active electrode and the skin;
  • contact with liquid;
  • long application of HF currents;
  • incorrect application of the patient-plate.

To avoid or reduce the common HF electrosurgical risks it is very important to respect the rules and safety measurements exposed illustrate on the next chapter.